Switched and Interlocked Receptacles
Interlocked with Fuse or Breaker

FCB Window Series
20, 30 & 60 Amp
NEMA 4X; 12

The MENNEKES FCB Series of Switched and Interlocked Receptacles feature a Fuse or Circuit Breaker Enclosure option. A hinged window provides access to a separate circuit breaker or fuse block to provide for cost effective supplemental protection at the receptacle load. Offered in 20, 30 and 60 Amp, units are compatible with IEC 60309-2 plug configurations.

Rated 4X; 12, receptacles feature a patented interlock mechanism which prohibits the HP rated switch from being turned "ON" unless the plug is fully inserted. The plug cannot be removed unless the switch is in the "OFF" position.


Features and Benefits
  • Factory Wired - Single Unit Construction - Eliminates installation of separate receptacle, switch and overload components. Receptacle is pre-wired from disconnect switch or fuse block depending upon installation requirement for fusing or cicuit breaker protection.
  • Modular Design - Separate breaker, fuse block and switch components allow for conformity to installed plant standards and facilitate service requirements.
  • Accessibility of Breaker or Fuses - Hinged access window allows for convenient reset of breaker or access to removable fuse holders with Type J Fuse Block option.
  • NEMA 4X; 12 Enclosure - Features a poured-in seamless gasket for the ultimate seal. Valox® material is impact modified and resistant to caustic and acidic environments.
  • Padlockable Handle - Rugged low profile design to meet OSHA LO/TO requirements. (Reg. 1910.147)
  • Auxiliary Contacts - An option for PLC interface. Add suffix "M2" for factory mounted switch contacts. Options available for field installation.

Ordering Information

Click on Product Catalog No. for PDF
Amp Configuration Voltage Max HP Rating+ Catalog No. Fused* Catalog No. Circuit Breaker*
20 3 Pole
4 Wire
125/250
3Ø250
3Ø480
.5; 1
5
10
ME 420MIF12-W
ME 420MIF9-W
ME 420MIF7-W
ME 420MICB12
ME 420MICB9
ME 420MICB7
30 3 Pole
4 Wire
125/250
3Ø250
3Ø480
1; 3
7.5
15
ME 430MIF12-W
ME 430MIF9-W
ME 430MIF7-W
ME 430MICB12
ME 430MICB9
ME 430MICB7
4 Pole
5 Wire
3ØY120/208
3ØY277/480
3ØY347/600
7.5
15
15
ME 530MIF9-W
ME 530MIF7-W
ME 530MIF5-W
ME 530MICB9
ME 530MICB7
ME 530MCB5
60 3 Pole
4 Wire
125/250
3Ø250
3Ø480
3Ø600
2.5; 7.5
15
30
35
ME 460MIF12-W
ME 460MIF9-W
ME 460MIF7-W
ME 460MIF5-W
ME 460MICB12
ME 460MICB9
ME 460MICB7
ME 460MICB5
4 Pole
5 Wire
3ØY120/208
3ØY277/480
15
30
ME 560MIF9-W
ME 560MIF7-W
ME 560MICB9
ME 560MICB7
+ Requires use of time delay fuses with fused Cat. Nos.
*Catalog No. requires use of a Suffix Designation when factory supplies fuse block or breaker.
3 Wire Configuration Available - consult factory for Cat. Nos.

Compliances
  • Listed 508 - Industrial Control Equipment
  • Listed 1682 and 1686 - Plugs and Receptacles, Pin and Sleeve Type
  • To CSA 22.2 No. 4-M89 & No. 4-M91
  • IEC 60309-1; IEC 60309-2
  • Enclosure: NEMA Type 4X; 12
  • UL94-5V Flame Rating
  • UV Stabilized Material
  • IP66

Auxiuliary Contacts: 1 N/O, 10A 600VAC
DescriptionCatalog No.
For 20 & 30 Amp Interlocked ReceptacleME 30AUX
For 60 Amp Interlocked ReceptacleME 80AUX

Replacement Switches
DescriptionCatalog No.
20 Amp - 2, 3 & 4 poleME 20MIX
30 Amp - 2, 3 S 4 poleME 30M1X
60 Amp - 2, 3 S 4 poleME 60 MIX
Approximate Dimensions (in inches)
20 Amp
4 Wire
30 Amp
4 Wire
30 Amp
5 Wire
60 Amp
4 Wire & 5 Wire
a
b
c
d
e

g.
h
14.33
5.28
6.12
13.66
4.59
0.25
0.32
15.37
14.33
5.28
6.50
13.66
4.59
0.25
0.32
16.06
114.33
5.28
6.61
13.66
4.59
0.25
0.32
16.18
18.11
7.09
7.56
17.32
6.25
0.32
0.32
19.56